Analog (ch 1-4, 8 byte)
Configuration file fields
This section is autogenerated from the Rule Schema.
Analog, channel 1-4 (1 ms) output.analog_1_4
State output.analog_1_4.state
Type |
Default |
Options |
---|---|---|
integer |
1 |
Disable: |
ID Format output.analog_1_4.id_format
ID format of the message
Type |
Default |
Options |
---|---|---|
integer |
0 |
Standard (11-bit): |
Message ID (hex) output.analog_1_4.id
ID of the message in hex. Example: 00435354.
Type |
Default |
---|---|
string |
01 |
Trigger method output.analog_1_4.trigger
Transmission trigger method. Push: Signal is periodically transmitted. Poll: Signal is transmitted on request
Type |
Default |
Options |
---|---|---|
integer |
0 |
Push: |
Frame layout
Note
The frame layout is defined in the CANmod.input DBC file
The analog channel 1-4 frame contains the following information.
Name |
Bitpos |
Length |
Factor |
Offset |
Min |
Max |
Unit |
---|---|---|---|---|---|---|---|
Analog 1 |
0 |
16 |
0.625 |
0 |
0 |
10000 |
mV |
Analog 2 |
16 |
16 |
0.625 |
0 |
0 |
10000 |
mV |
Analog 3 |
32 |
16 |
0.625 |
0 |
0 |
10000 |
mV |
Analog 4 |
48 |
16 |
0.625 |
0 |
0 |
10000 |
mV |
Analog X
Contains an analog reading from the specific channel.