Thermocouple high resolution top (5 Hz, 8 byte)
Configuration file fields
This section is autogenerated from the Rule Schema.
Thermocouple high resolution top (200 ms) output.thermocouple_hr_top
Readings from top row temperature sensors
State output.thermocouple_hr_top.state
Type |
Default |
Options |
---|---|---|
integer |
1 |
Disable: |
ID Format output.thermocouple_hr_top.id_format
ID format of the message
Type |
Default |
Options |
---|---|---|
integer |
0 |
Standard (11-bit): |
Message ID (hex) output.thermocouple_hr_top.id
ID of the message in hex. Example: 00435354.
Type |
Default |
---|---|
string |
01 |
Trigger method output.thermocouple_hr_top.trigger
Transmission trigger method. Push: Signal is periodically transmitted. Poll: Signal is transmitted on request
Type |
Default |
Options |
---|---|---|
integer |
0 |
Push: |
Frame layout
The frame layout is defined in the CANmod.temp DBC file.
The temperature frame contains the Cold-Junction (ambient) temperature and two sets (top) of thermocouple sensor status and temperature readings.
TL (Top-Left) and TR (Top-Right) refer to the locations of the thermocouple sensor connectors (see Connector back).
For more information on the signal interpretation see Thermocouple (5 Hz, 8 byte).